Klemm KR709-2
Pile Diameter |
Minimum
Operating Height |
Minimum Tracking
Height |
Minimum Distance from face of
Wall to Centre of Pile
|
Auger & Case |
|
|
|
340/300mm |
From 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
406/350mm |
From 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
508/450mm |
From 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
660/600mm |
from 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
CFA |
|
|
|
300mm CFA |
from 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
350mm CFA |
from 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
400mm CFA |
from 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
450mm CFA |
from 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
500mm CFA |
from 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
600mm CFA |
from 3.7 to 8.8m |
2950/3100mm |
800mm, 1000mm (corner) |
600mm,800mm (Corner) |
|
Much tighter tolerances can be achieved than indicated above, as tight as 100mm from the face of a pile to an existing wall subject to access and piling rig orientation. Please call us for job specific requirements.